Wireless Instrumentation
Gauge Pressure Field Unit

 
The Gauge Pressure Field Unit is self powered and contains a pressure sensor, signal conditioning circuitry and a RF transceiver operating in the 902 MHz to 928 MHz ISM license free band. Remote mount sensors and high-gain antennas are available as options. The field units are completely free of field wiring for power and signal transmission, making them ideal for automating remote pressure monitoring in all types of industrial environments. Data from the sensor is transmitted to the Base Radio for centralized monitoring and data acquisition. The user may specify sample and transmit updates between once per second and once per minute. Transmit rate changes can also be triggered based on events that are defined in terms of measurement limits or rates of movement. This function allows for maximization of battery life while ensuring that all important process events are monitored. 

 
 
Accuracy
  • ± 0.1 % of sensor URL including combined effects of linearity, hysteresis, repeatability and temperature (applies to standard unit without isolating seals) NOTE: addition of seals will reduce accuracy due to thermal effects of fill fluid.
Output Resolution
  • 24 bit Analog to Digital conversion - see specification sheets for the Base Radio and Analog Output Modules for descriptions of analog and digital output options.
Power Characteristics
  • Self-contained power
  • 'C' Size 3.6 V lithium battery
  • Up to twenty (20) year battery life (depends on sample rate and RF update rate), field replaceable
Self-Diagnostics
  • Low battery alarm - indicates the need to replace the battery (approximately one month warning) Contains extensive self-checking software and hardware that continuously monitors the operation. Any sensor or device parameter out of spec is identified and reported
Materials of Construction
  • Type 316 stainless steel base and diaphragm Standard 1/2" MNPT (other options available) GE Lexan© cover. V-0 rating and UV stable
Random Vibration Characteristics
  • Certified to withstand 6 g's, 15 minutes per axis from 9 - 500Hz
Industrial Certification
  • Rated for industrial use -40° F to 185° (-40° C to 85° C) FM NEMA 4 or 4X weather-proof enclosure FM rated intrinsically safe for Class I, II, III; Div 1, Groups A, B, C, D, E, F & G; Class I, II, III, Div 2, Groups A, B, C, D, F & G. CSA Type 4 or 4X weather-proof enclosure CSA rated intrinsically safe for Class I, Div 1, Groups A, B, C & D. Class II, Div 1, Groups E, F & G; Class III, Div 1 ATEX II1G, EEx1a IIC T4
 Stability
  • Combined zero and span stability: less than ± 0.1% of sensor URL per year at 70°F
Operating Ambient Environment
  • -40° F to +250° F (-40° C to +121° C) process temperature, steady state
  • -40° F to +230° F (-40° C to +110° C) ambient temperature sensor
  • -40° F to +185° F (-40° C to +85° C) electronics
  • -4° F to +158° F (-20° C to +70° C) display (full visibility)
  • -40° F to +185° F (-40° C to +85° C) display (with reduced visibility)
  • Humidity Limits: 0 to 95 %, non-condensing
RF Characteristics
  • 902 MHz - 928 MHz Frequency Hopping Spread Spectrum (FHSS), FCC certified ISM license-free band Up to 3000' range from Base Radio with clear line of sight; 500' to 1000' typical range with obstructions The RF module in each Field Unit is individually tested and calibrated over the full temperature range to ensure reliable wireless operation
Local Configuration
  • Integrated LCD display with membrane switch buttons Display provides pressure reading and error messages, if applicable Configure sampling and RF parameters locally using membrane switch buttons
Operating Shock and Vibration
  • Certified per IEC EN00068 2-6 (vibration) and 2-27 (shock)
Electromagnetic Compatibility (CE Compliance)
  • Operates within specification in fields from 80 to 1,000 MHz with field strengths to 30 V/m. Meets EN 50082-1 general immunity standard and EN 55011 compatibility emissions standard
Intrinsic Safety Parameters
  • FM Class T4 for max operating temp = +85° C CSA Temp Code T3, operating temp = +85° C CSA Class I, Div 2 Temp Code T4, operating temp = +85°

Pressure Ranges

ModelUpper Range Limit (URL)Overload LimitSafety Limit
GP-x-x-55 PSIG10 PSIG30 PSIG
GP-x-x-1515 PSIG30 PSIG500 PSIG
GP-x-x-3030 PSIG60 PSIG500 PSIG
GP-x-x-100100 PSIG200 PSIG500 PSIG
GP-x-x-250250 PSIG500 PSIG1500 PSIG
GP-x-x-10001000 PSIG2000 PSIG10000 PSIG
GP-x-x-25002500 PSIG  
GP-x-x-50005000 PSIG12000 PSIG20000 PSIG